Account Holder? Login for Wholesale Pricing
 Call 1-800-661-9891   |   View Hours
Home  >  HVAC  >  Gas Valves  >  Residential Combustion Gas Valves  >  SV9541Q2561

Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2" x 1/2", for Intermittent Hot Surface Ignition Systems

  Click Here to View 360 Spin
  • Photo 1 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 2 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 3 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 4 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 5 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 6 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 7 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 8 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 9 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 10 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 11 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 12 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 13 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 14 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 15 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 16 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems
  • Photo 17 of SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2 x 1/2, for Intermittent Hot Surface Ignition Systems

1 of
Click Main Image to Enlarge
Grids Shown are 1" x 1"

  Click Here to View Part Videos
$74119
Special Order

 

SKU: SV9541Q2561

Resideo Logo

 


Resideo Honeywell SV9541Q2561 SmartValve Gas Valve, Nat.Gas/LP, Standard Open, 1/2" x 1/2", 2 Stage, for Intermittent Hot Surface Ignition Systems. The SmartValve® System Controls combine gas flow control and electronic intermittent pilot sequencing functions into a single unit. The Q3450 or Q3480 Pilot hardware supplies the low voltage igniter, flame sensor and pilot burner. These ignition system controls provide all gas ignition safety functions by controlling gas flow, ignition source, and a 120 Vac or 240 Vac combustion air blower. The controls also monitor the appliance airflow proving switch and limit string to assure proper appliance operation, and provide prepurge, postpurge, and timed trial for pilot ignition with 100 percent shutoff and continuous retry. Includes a diagnostic LED indicates system status.

Features:
These controls communicate directly with an electronic fan timer (ST9160 Electronic Fan Timer for single stage applications; ST9162 Electronic Fan Timer for two-stage applications) in typical forced warm air furnace applications.
It can directly interface with the appropriate power supplies and a system thermostat for additional appliance applications.
When controlled directly by a thermostat, these controls do not provide a postpurge function, because power to the control is removed when the thermostat call for heat ends.
The Systems are suitable for a wide range of fan-assisted combustion gas-fired appliances including furnaces, rooftop furnaces, boilers, unit heaters, infrared heaters, water heaters and commercial cooking appliances.
Includes a Natural to LP Conversion Kit
Mounting is 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Stock shown on hand can change at anytime without notice or may already be spoken for. Please inquire by phone to confirm precise amounts available at that time.
Alberta
Edmonton (DC): 0
Edmonton (South): 0
Calgary: 0
British Columbia
Richmond: 0
Surrey: 0
Manitoba
Winnipeg: 0
Saskatchewan
Saskatoon: 0
Ontario
Hamilton: 0
London: 0
Mississauga: 0
Scarborough: 0
Windsor: 0
These are estimated number of days using averages of past orders for inventory arriving to each branch location and are not guaranteed. If you need to verify manufacturer stock please email customercare@amresupply.com or call us at 1-800-661-9891.
Amre Branch # of Days
Calgary: 21
Edmonton Downtown: 23
Edmonton South: 18
Hamilton: 20
London: 15
Mississauga: 18
Richmond: 22
Saskatoon: 19
Scarborough: 16
Surrey: 22
Windsor: 10
Winnipeg: 16


Product Specifications

  Ambient Temperature Range (C): -40 C to +79 C
  Ambient Temperature Range (F): -40 F to +175 F
  Body Pattern: Straight-through
  Capacity (ft³/hr): Maximum at 1 in. P.D.--150 ft³/hr; Maximum--200 ft³/hr; Minimum--20 ft³/hr
  Capacity (m³/hr): Maximum at 1 in. P.D.--4.2 m³/hr; Maximum--5.7 m³/hr; Minimum--0.6 m³/hr
  CSA Approved: CSA International: 112395
  Dimensions (in): 3.2 in. wide x 4.9 in. high x 4.1 in.long
  Dimensions (mm): 81 mm wide x124 mm high x 104 mm long.
  Electrical Rating (amp): 24 Vac
  Flame Failure Response Time (sec): 1.6 sec @ 3 µA
  Flame Sense: HSI
  Frequency: 60 Hz
  Ignition Sequence: Intermittent Pilot
  Ignition Source: Pilot
  Ignition System Type: Intermittent Hot Surface Pilot Ignition
  Ignition Trials To Lockout: Continuous retry
  Ignition Trial Time (sec): 90 sec
  Inlet/Outlet Size (in): 1/2 in. NPT x 1/2 in. NPT
  Opening Characteristics: Standard 2-stage
  Pilot Gas Outlet: Yes
  Post Purge: 30 seconds
  PrePurge: 15 seconds
  Pressure Ratings (kPa): 3.5 kPa
  Pressure Ratings (psi): 1/2 psi
  Pressure Regulator Setting (kPa): 0.42 kPa low; 0.80 kPa high
  Pressure Regulator Setting (psi): 1.7 in. WC low; 3.2 in. WC high
  Pressure Tapping: 1/8 in. - NPT
  Type of Gas: Natural/LP