Bruce T - Edmonton, AB (Dec 15, '16)
| Model: Coleman G8V10016UHB11C furnace
Symptom: Furnace will not fire up as flame sensor is dirty. The sensor rod gets a coating from the gas flame, which can be removed with emery/fine sand paper & reused, but it's good to have a back-up sensor on hand.
Repair Time: 15 Minutes
Tools: Philips head screwdriver.
This flame sensor is also a replacement for a Coleman (York?) furnace part 025-277773-000. Amre had it available at their Edmonton South counter. Very quick service from Amre & part works perfectly. Good job you guys!