Account Holder? Login for Wholesale Pricing
 Call 1-800-661-9891   |   View Hours
Home  >  HVAC  >  Furnace Repair Parts  >  Control Boards & Modules  >  50M56-743

White-Rodgers 50M56-743 HSI Integrated Control Board, Goodman

  • Photo 1 of 50M56-743 : White-Rodgers 50M56-743 HSI Integrated Control Board, Goodman
  • Photo 2 of 50M56-743 : White-Rodgers 50M56-743 HSI Integrated Control Board, Goodman
  • Photo 3 of 50M56-743 : White-Rodgers 50M56-743 HSI Integrated Control Board, Goodman
  • Photo 4 of 50M56-743 : White-Rodgers 50M56-743 HSI Integrated Control Board, Goodman
  • Photo 5 of 50M56-743 : White-Rodgers 50M56-743 HSI Integrated Control Board, Goodman
  • Photo 6 of 50M56-743 : White-Rodgers 50M56-743 HSI Integrated Control Board, Goodman
  • Photo 7 of 50M56-743 : White-Rodgers 50M56-743 HSI Integrated Control Board, Goodman

1 of
Click Main Image to Enlarge
Grids Shown are 1" x 1"

  Click Here to View Part Videos
$23472
In-Stock for Same Day Shipping

If ordered before 4pm
Click here to check branch on hand inventory

 

SKU: 50M56-743

Emerson Logo

 


White-Rodgers 50M56-743 HSI Integrated Furnace Control. OEM Replacement.
Use with Goodman, Amana Multi-Speed 2 Stage Furnaces
Replaces 0130F00006, 0130F00006S, 50M56-743, 50M56-289, PCB00109, PCBBF109, PCBBF122, PCBBF122S, PCBBF132 & PCBBF132S
Use with Select Amana & Goodman Furnaces.
Fits many, but not all of the following model series starting with these prefixes. GCH, GMH.
If you are unsure this is the correct part you require Please contact customer support with your exact model.

FEATURES
• System diagnostic LED with fault recall.
• Multi-speed circulator.
• One or two-stage gas valve.
SPECIFICATIONS
Operating Temperature. . . . . . . . . . . . . . . . . . . -40 to 176°F
Humidity Range . . . . . . . . . . . . . . . . . . . . . . . . 5% to 93% RH (non-condensing)
Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Snap in standoffs
Electrical Ratings @ 77°F (25°C)
Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . 25 VAC 50 / 60 Hz
Maximum Input Current @ 30 VAC . . . . . . . . . 0.45 amp
Relay Load Ratings
Valve Relay. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 amp @ 25 VAC 50 / 60 Hz 0.6 pf
Ignitor Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.0 amp @ 120 VAC 50 / 60 Hz
Inducer Relay . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 FLA-3.5 LRA @ 120 VAC
Circulator Relay . . . . . . . . . . . . . . . . . . . . . . . . 14.5 FLA-25.0 LRA @ 120 VAC
Flame Current Requirements
Minimum current to insure fl ame detection. . . . 1 uA DC
Maximum current for non-detection . . . . . . . . . 0.10 uA DC
Maximum allowable leakage resistance. . . . . . 100 M ohms
Timing Spec (@ 60 Hz) maximum
Flame establishing time . . . . . . . . . . . . . . . . . . 0.8 sec
Flame failure response time . . . . . . . . . . . . . . . 2.0 seconds
NOTE: At 50 Hz, all timing specifi cations should be increased by 20%.
Stock shown on hand can change at anytime without notice or may already be spoken for. Please inquire by phone to confirm precise amounts available at that time.
Alberta
Edmonton (DC): 3
Edmonton (South): 0
Calgary: 2
British Columbia
Richmond: 0
Surrey: 0
Manitoba
Winnipeg: 0
Saskatchewan
Saskatoon: 0
Ontario
Hamilton: 1
London: 0
Mississauga: 2
Scarborough: 0
Windsor: 2
These are estimated number of days using averages of past orders for inventory arriving to each branch location and are not guaranteed. If you need to verify manufacturer stock please email customercare@amresupply.com or call us at 1-800-661-9891.
Amre Branch # of Days
Calgary: 17
Edmonton Downtown: 19
Edmonton South: 16
Hamilton: 16
London: 14
Mississauga: 16
Richmond: 19
Saskatoon: 16
Scarborough: 13
Surrey: 17
Windsor: 13
Winnipeg: 16

Product Downloads
  Product Specifications
  More Information

Customer Reviews


  Add a Customer Review

0130F00006 0130F00006S 50M56-289
786710548666 B00M21O6QO B01IU7P3BK
PCB00109 PCBBF122 PCBBF132