Account Holder? Login for Wholesale Pricing
 Call 1-800-661-9891   |   View Hours
Home  >  HVAC  >  Gas Valves  >  Residential Combustion Gas Valves  >  SV9601M4571

Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4" x 3/4", for Intermittent Hot Surface Ignition Systems

  Click Here to View 360 Spin
  • Photo 1 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 2 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 3 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 4 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 5 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 6 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 7 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 8 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 9 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 10 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 11 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 12 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 13 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 14 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 15 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 16 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 17 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 18 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems
  • Photo 19 of SV9601M4571 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Opening, 3/4 x 3/4, for Intermittent Hot Surface Ignition Systems

1 of
Click Main Image to Enlarge
Grids Shown are 1" x 1"

  Click Here to View Part Videos
$80366
Special Order

 

SKU: SV9601M4571

Resideo Logo

 


Resideo Honeywell SV9601M4571 SmartValve Gas Valve, Nat.Gas/LP, Standard Open, 3/4" x 3/4", for Intermittent Hot Surface Ignition Systems. The SmartValve® System Controls combine gas flow control and electronic intermittent pilot sequencing functions into a single unit. This product family offers several different intermittent pilot sequences for a wide range of applications. The specific application of the SmartValve System is the responsibility of the appliance manufacturer. They are directly compatible with the Q3450 or Q3480 Intermittent Pilot burners used with the original controls on the appliance.

Features:
Suitable for a wide range of gas-fired appliances including residential furnaces, roof-top furnaces, residential boilers, unit heaters, infrared heaters, space heaters and commercial cooking units.
Ignition sequence includes timed trial for ignition.
Includes Two 3/4 x 1/2 in. reducer bushings and a Natural to LP Conversion Kit
Mounting is 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Stock shown on hand can change at anytime without notice or may already be spoken for. Please inquire by phone to confirm precise amounts available at that time.
Alberta
Edmonton (DC): 0
Edmonton (South): 0
Calgary: 0
British Columbia
Richmond: 0
Surrey: 0
Manitoba
Winnipeg: 0
Saskatchewan
Saskatoon: 0
Ontario
Hamilton: 0
London: 0
Mississauga: 0
Scarborough: 0
Windsor: 0
These are estimated number of days using averages of past orders for inventory arriving to each branch location and are not guaranteed. If you need to verify manufacturer stock please email customercare@amresupply.com or call us at 1-800-661-9891.
Amre Branch # of Days
Calgary: 21
Edmonton Downtown: 23
Edmonton South: 18
Hamilton: 20
London: 15
Mississauga: 18
Richmond: 22
Saskatoon: 19
Scarborough: 16
Surrey: 22
Windsor: 10
Winnipeg: 16


Product Specifications

  Ambient Temperature Range (C): -40 C to +79 C
  Ambient Temperature Range (F): -40 F to +175 F
  Body Pattern: Straight-through
  Capacity (ft³/hr): Maximum at 1 in. P.D.--300 ft³/hr; Maximum--415 ft³/hr; Minimum--30 ft³/hr
  Capacity (m³/hr): Maximum at 1 in. P.D.--8.5 m³/hr; Maximum--11.8 m³/hr; Minimum--0.8 m³/hr
  CSA Approved: CSA International: 112395
  Dimensions (in): 3.2 in. wide x 4.9 in. high x 4.1 in.long
  Dimensions (mm): 81 mm wide x124 mm high x 104 mm long.
  Electrical Rating (amp): 24 Vac
  Flame Failure Response Time (sec): 1.6 sec @ 3 µA
  Flame Sense: HSI
  Frequency: 50 Hz; 60 Hz
  Ignition Sequence: Intermittent Pilot
  Ignition Source: Pilot
  Ignition System Type: Intermittent Hot Surface Pilot Ignition
  Ignition Trials To Lockout: continuous retry
  Ignition Trial Time (sec): 90 sec
  Inlet/Outlet Size (in): 3/4 in. NPT x 3/4 in. NPT.
  Opening Characteristics: Standard
  Pilot Gas Outlet: Yes
  PrePurge: None
  Pressure Ratings (kPa): 3.5 kPa
  Pressure Ratings (psi): 1/2 psi
  Pressure Regulator Setting (kPa): 0.87 kPa
  Pressure Regulator Setting (psi): 3.5 in. WC
  Pressure Tapping: 1/8 in. - NPT
  Type of Gas: Natural (LP with included conversion kit)