Taco Boiler Feed/Backflow Preventer, 1/2", Threaded

  Click Here to View 360 Spin
  • Photo 1 of 3492-050-BT1 : Taco Boiler Feed/Backflow Preventer, 1/2, Threaded
  • Photo 2 of 3492-050-BT1 : Taco Boiler Feed/Backflow Preventer, 1/2, Threaded
  • Photo 3 of 3492-050-BT1 : Taco Boiler Feed/Backflow Preventer, 1/2, Threaded
  • Photo 4 of 3492-050-BT1 : Taco Boiler Feed/Backflow Preventer, 1/2, Threaded
  • Photo 5 of 3492-050-BT1 : Taco Boiler Feed/Backflow Preventer, 1/2, Threaded
  • Photo 6 of 3492-050-BT1 : Taco Boiler Feed/Backflow Preventer, 1/2, Threaded
  • Photo 7 of 3492-050-BT1 : Taco Boiler Feed/Backflow Preventer, 1/2, Threaded
  • Photo 8 of 3492-050-BT1 : Taco Boiler Feed/Backflow Preventer, 1/2, Threaded
  • Photo 9 of 3492-050-BT1 : Taco Boiler Feed/Backflow Preventer, 1/2, Threaded
  • Photo 10 of 3492-050-BT1 : Taco Boiler Feed/Backflow Preventer, 1/2, Threaded
  • Photo 11 of 3492-050-BT1 : Taco Boiler Feed/Backflow Preventer, 1/2, Threaded
  • Photo 12 of 3492-050-BT1 : Taco Boiler Feed/Backflow Preventer, 1/2, Threaded
  • Photo 13 of 3492-050-BT1 : Taco Boiler Feed/Backflow Preventer, 1/2, Threaded
  • Photo 14 of 3492-050-BT1 : Taco Boiler Feed/Backflow Preventer, 1/2, Threaded

1 of
Click Main Image to Enlarge
Grids Shown are 1" x 1"

$31820
In-Stock for Same Day Shipping

If ordered before 4pm
Click here to check branch on hand inventory

 

SKU: 3492-050-BT1

Taco Logo

 


Taco 3450-T2 Boiler Feed and Backflow Preventer, 1/2".

Taco’s combination Backflow Preventer and Boiler Feed Valve (PRV) is designed for use in today’s Hydronic heating systems to protect against possible water contamination from the heating system water flowing back into the potable water supply.

Features:
The Taco combination valve showcases a fast fill button with automatic reset
The integral Backflow Preventer prevents the back flow of non potable heating system water into the Potable water supply.
The Boiler Feed Valve (PRV) reduces incoming pressure and automatically maintains that system pressure to the valves adjustable pressure set point
Stock shown on hand can change at anytime without notice or may already be spoken for. Please inquire by phone to confirm precise amounts available at that time.
Alberta
Edmonton (DC): 1
Edmonton (South): 0
Calgary: 0
British Columbia
Richmond: 0
Surrey: 0
Manitoba
Winnipeg: 0
Saskatchewan
Saskatoon: 0
Ontario
Hamilton: 0
London: 0
Mississauga: 0
Scarborough: 0
Windsor: 0
These are estimated number of days using averages of past orders for inventory arriving to each branch location and are not guaranteed. If you need to verify manufacturer stock please email customercare@amresupply.com or call us at 1-800-661-9891.
Amre Branch # of Days
Calgary: 36
Edmonton Downtown: 20
Edmonton South: 3
Hamilton: 6
London: 3
Mississauga: 11
Richmond: 5
Saskatoon: 17
Scarborough: 17
Surrey: 21
Windsor: 3
Winnipeg: 11


Product Specifications

  Connection: 1/2" x 1/2"
  Factory Setting: 12 psi
  Maximum Flow (GPM): 25 gpm (8 ft / sec)
  Maximum Inlet Pressure (psi): 150 psi
  Maximum Temperature: 210°F
  Mounting Position: Horizontal Flow with Atmospheric Vent toward the floor
  Recommended Setting Range: 10-50 psi +/-3 psi