Account Holder? Login for Wholesale Pricing
 Call 1-800-661-9891   |   View Hours
Home  >  HVAC  >  Furnace Repair Parts  >  Control Boards & Modules  >  50M56U-801

White-Rodgers 50M56U-801 Integrated HSI Furnace Control Board, Lennox, Allied Air

  • Photo 1 of 50M56U-801 : White-Rodgers 50M56U-801 Integrated HSI Furnace Control Board, Lennox, Allied Air
  • Photo 2 of 50M56U-801 : White-Rodgers 50M56U-801 Integrated HSI Furnace Control Board, Lennox, Allied Air
  • Photo 3 of 50M56U-801 : White-Rodgers 50M56U-801 Integrated HSI Furnace Control Board, Lennox, Allied Air
  • Photo 4 of 50M56U-801 : White-Rodgers 50M56U-801 Integrated HSI Furnace Control Board, Lennox, Allied Air
  • Photo 5 of 50M56U-801 : White-Rodgers 50M56U-801 Integrated HSI Furnace Control Board, Lennox, Allied Air
  • Photo 6 of 50M56U-801 : White-Rodgers 50M56U-801 Integrated HSI Furnace Control Board, Lennox, Allied Air
  • Photo 7 of 50M56U-801 : White-Rodgers 50M56U-801 Integrated HSI Furnace Control Board, Lennox, Allied Air

1 of
Click Main Image to Enlarge
Grids Shown are 1" x 1"

  Click Here to View Part Videos
$27932
In-Stock for Same Day Shipping

If ordered before 4pm
Click here to check branch on hand inventory

 

SKU: 50M56U-801

Emerson Logo

 


White-Rodgers 50M56U-801 Single Stage | Direct | HSI Integrated Furnace Control Kit DIRECT REPLACEMENTment.

The 50M56U-801 services most current Lennox / Allied Air Enterprises single stage furnaces with 2 or 3 speed PSC
motors and 120V HSI single stage furnace controls.
Kit includes wiring harnesses, control with Fault Recall and LED display, and dipswitches to set blower delays.

Replaces Lennox 81W03, 56W19, 94W83, and 74W03
service platforms - which have no other competitive replacements.
It employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan.

Includes
• 50M56-801 Integrated Furnace Control
• 2 Harness Assemblies
• Control Label
• Wire Ties
• Installation Instruction

Relay Load Ratings
Valve Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 amp @ 25 VAC 50 / 60 Hz 0.6 pf
Ignitor Relay . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 amp @ 120 VAC 50 / 60 Hz
Inducer Relay . . . . . . . . . . . . . . . . . . . . . . . . . 2.8 amp @ 120 VAC
Circulator Relay . . . . . . . . . . . . . . . . . . . . . . . . 10.0 FLA-25.0 LRA @ 120 VAC
Humidifier Load . . . . . . . . . . . . . . . . . . . . . . . . 1.0 amp @ 24 VAC or 120 VAC
Electronic Air Cleaner . . . . . . . . . . . . . . . . . . . 1.0 amp @ 120 VAC
Flame Current Requirements
Minimum current to insure flame detection . . . 0.25 uA DC*
Maximum current for non-detection . . . . . . . . . 0.10 uA DC*
Maximum allowable leakage resistance . . . . . 100 M ohms
Timing Spec (@ 60 Hz) maximum
Flame establishing time . . . . . . . . . . . . . . . . . . 0.8 sec
Flame failure response time . . . . . . . . . . . . . . 2.0 seconds


Stock shown on hand can change at anytime without notice or may already be spoken for. Please inquire by phone to confirm precise amounts available at that time.
Alberta
Edmonton (DC): 1
Edmonton (South): 1
Calgary: 1
British Columbia
Richmond: 1
Surrey: 0
Manitoba
Winnipeg: 0
Saskatchewan
Saskatoon: 0
Ontario
Hamilton: 0
London: 0
Mississauga: 1
Scarborough: 0
Windsor: 0
These are estimated number of days using averages of past orders for inventory arriving to each branch location and are not guaranteed. If you need to verify manufacturer stock please email customercare@amresupply.com or call us at 1-800-661-9891.
Amre Branch # of Days
Calgary: 17
Edmonton Downtown: 19
Edmonton South: 16
Hamilton: 16
London: 14
Mississauga: 16
Richmond: 19
Saskatoon: 16
Scarborough: 13
Surrey: 17
Windsor: 13
Winnipeg: 16


Product Specifications

  Cool Fan Off Delay: 2 / 60*
  Cool Fan On Delay: 2
  Flame Failure Response Time (sec): 2.0 sec
  Heat Off Fan Delay: 60 / 90 / 120* / 180
  Heat On Fan Delay: 30* / 45
  Humidity Range: 5% to 93% RH (non-condensing)
  Mounting Type: Surface mount standoffs
  Post Purge: 5 sec
  PrePurge: 15 sec
  Temperature Range (F): -40° to 175°F (-40° to 80°C)
  Volts (V): .45A @ 25 VAC