ICM Controls ICM293 IPI Gas Ignition Control Board
Intermittent pilot gas ignition control. For use with intermittent pilot boilers, furnaces and other heating appliances.Microprocessor-based precision. Monitors timing, trial for ignition, flame sensing and lockout Remote flame sensing. 100% lockout safety feature.
Works with both Natural and LP gas systems.Status LED for fault codes to aid in troubleshooting
Replaces Lennox 30W33 and JCI G776RGD-14 series.
Specifications:
Control Voltage: Line 24V (18-30 VAC), 50/60Hz
Anticipator Setting: 0.2A plus valve load @ 24VAC
Prepurge: 15 seconds
Trial for Ignition: 85 seconds
Lockout: 60 minutes
Flame Failure Response Time: 0.5 seconds
LED: See product label for error codes
Weight/Dimensions:
Weight: 0.45
Height: 2
Width: 5.375