Account Holder? Login for Wholesale Pricing
 Call 1-800-661-9891   |   View Hours
Home  >  HVAC  >  Furnace Repair Parts  >  Control Boards & Modules  >  50M56U-751

White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier

  Click Here to View 360 Spin
  • Photo 1 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 2 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 3 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 4 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 5 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 6 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 7 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 8 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 9 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 10 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 11 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 12 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 13 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 14 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 15 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 16 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 17 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 18 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 19 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier
  • Photo 20 of 50M56U-751 : White-Rodgers 50M56U-751 HSI Ignition Control Module, 120V, Single Stage, Carrier

1 of
Click Main Image to Enlarge
Grids Shown are 1" x 1"

  Click Here to View Part Videos
$30144
In-Stock for Same Day Shipping

If ordered before 4pm
Click here to check branch on hand inventory

 

SKU: 50M56U-751

Emerson Logo

 


White-Rodgers 50M56U-751 Ignition Control Module for HSI ( Hot Surface Ignition ) Single Stage OEM Replacement.
Use on Carrier & ICM Furnaces with 120V Ignitors.
Replaces Carrier 325878-751, HK42FZ004, HK42FZ007, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ013, HK42FZ016, HK42FZ034,
White-Rodgers 50M56-751 & ICM ICM28.
Will Replaces Virtually All Carrier Single Stage HSI Controls with 120V Ignitors. & WR 50M56-751.
Easy Install Kit includes everything you need for quick and accurate replacement: • Ignition Control Module • Installation Instructions and OEM Cross-Reference • Set of Interconnect Harnesses • Bag of Accessories.
Features: • System Diagnostic LED with Fault Recall • Low-Speed Continuous Fan Option • 120 VAC Ignitor Output • 120 or 24 VAC Humidifier Output • 120 VAC Electronic Air Cleaner Output • Self-Test Installation Routine.
Specifications:
Electrical Ratings: [@ 77°F (25°C)], Input Voltage: 25 VAC 50/60 Hz, Max. Input Current @ 25 VAC: 0.45 amp.
Operating Temperature Range -40° to 175°F (-40° to 80°C).
Relay Load Ratings: Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf, Ignitor Relay: 6.0 amp @ 120 VAC 50/60 Hz (resistive),
Inducer Relay: 2.2 FLA-3.5 LRA @ 120 VAC, Circulator Relay: 14.5 FLA-25.0 LRA @ 120 VAC.
Flame Current Requirements: Minimum current to insure flame detection: 1 μa DC* Maximum current for non-detection: 0.1 μa DC*
Maximum allowable leakage resistance: 100 M ohms.
Timing Specifications (@ 60 Hz**): Flame Establishing Time: Max. 0.8 sec, Flame Failure Response Time: Max. 2.0 sec, **At 50 Hz, all timing specifications should be increased by 20%.
Dimensions : 5.25" W x 7" H x 1.25" D
Timing Specifications ( Seconds ): *These times will vary depending on option switch position.
Pre-purge: 30.
Ignitor warm-up: (1st 64 attempts) 17, Maximum Ignitor warm-up 19
Ignition activation period: 2
Trial for ignition period: 4
Recycles: 3
Retries: 2 Times
Valve sequence period: 12
Interpurge: 60
Post-purge: 25
Lockout time : 275
Heat delay to fan ON*: 25/60
Heat delay to fan OFF*: 90/120
Cool delay to fan ON: 2
Cool delay to fan OFF*: 5/90
Auto reset: 60 minutes


Stock shown on hand can change at anytime without notice or may already be spoken for. Please inquire by phone to confirm precise amounts available at that time.
Alberta
Edmonton (DC): 4
Edmonton (South): 2
Calgary: 6
British Columbia
Richmond: 1
Surrey: 0
Manitoba
Winnipeg: 1
Saskatchewan
Saskatoon: 8
Ontario
Hamilton: 2
London: 0
Mississauga: 2
Scarborough: 0
Windsor: 0
These are estimated number of days using averages of past orders for inventory arriving to each branch location and are not guaranteed. If you need to verify manufacturer stock please email customercare@amresupply.com or call us at 1-800-661-9891.
Amre Branch # of Days
Calgary: 17
Edmonton Downtown: 19
Edmonton South: 16
Hamilton: 16
London: 14
Mississauga: 16
Richmond: 19
Saskatoon: 16
Scarborough: 13
Surrey: 17
Windsor: 13
Winnipeg: 16

Product Downloads
  Installation Instructions- English
  Product Specifications
  Installation Instructions

Customer Reviews


  Add a Customer Review

2I-CQ6G-T06R 325878751 325878-751 786710550485
B00QW2QPUY B0145O4UKC HK42FZ004 HK42FZ007
HK42FZ008 HK42FZ009 HK42FZ011 HK42FZ012
HK42FZ013 HK42FZ016