Resideo Honeywell Triple Aquastat Relay Controller, High Limit, Horizontal Mount

  Click Here to View 360 Spin
  • Photo 1 of L8124L1011 : Resideo Honeywell Triple Aquastat Relay Controller, High Limit, Horizontal Mount
  • Photo 2 of L8124L1011 : Resideo Honeywell Triple Aquastat Relay Controller, High Limit, Horizontal Mount
  • Photo 3 of L8124L1011 : Resideo Honeywell Triple Aquastat Relay Controller, High Limit, Horizontal Mount
  • Photo 4 of L8124L1011 : Resideo Honeywell Triple Aquastat Relay Controller, High Limit, Horizontal Mount
  • Photo 5 of L8124L1011 : Resideo Honeywell Triple Aquastat Relay Controller, High Limit, Horizontal Mount
  • Photo 6 of L8124L1011 : Resideo Honeywell Triple Aquastat Relay Controller, High Limit, Horizontal Mount
  • Photo 7 of L8124L1011 : Resideo Honeywell Triple Aquastat Relay Controller, High Limit, Horizontal Mount
  • Photo 8 of L8124L1011 : Resideo Honeywell Triple Aquastat Relay Controller, High Limit, Horizontal Mount
  • Photo 9 of L8124L1011 : Resideo Honeywell Triple Aquastat Relay Controller, High Limit, Horizontal Mount
  • Photo 10 of L8124L1011 : Resideo Honeywell Triple Aquastat Relay Controller, High Limit, Horizontal Mount
  • Photo 11 of L8124L1011 : Resideo Honeywell Triple Aquastat Relay Controller, High Limit, Horizontal Mount
  • Photo 12 of L8124L1011 : Resideo Honeywell Triple Aquastat Relay Controller, High Limit, Horizontal Mount
  • Photo 13 of L8124L1011 : Resideo Honeywell Triple Aquastat Relay Controller, High Limit, Horizontal Mount

1 of
Click Main Image to Enlarge
Grids Shown are 1" x 1"

$68423
Special Order

Click here for estimated arrival time to your local branch

 

SKU: L8124L1011

Resideo Logo

 


Resideo Honeywell L8124L1011 Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service.

Features :
Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems.
Provide multizone control by using a separate circulator and R845 Relay for each zone.
Include diaphragm powerhead and Micro Switch™ assembly that respond to temperature changes in boiler water.
Mount directly to boiler.
Select models include large transformers and extra terminals for supplying power to low voltage zone valves.
Require 24 Vac thermostat with heat anticipator set at 0.2 A (plus current draw of gas valve on L8124E).
TRADELINE models include tube of heat conductive compound and range stops.
Stock shown on hand can change at anytime without notice or may already be spoken for. Please inquire by phone to confirm precise amounts available at that time.
Alberta
Edmonton (DC): 0
Edmonton (South): 0
Calgary: 0
British Columbia
Richmond: 0
Surrey: 0
Manitoba
Winnipeg: 0
Saskatchewan
Saskatoon: 0
Ontario
Hamilton: 0
London: 0
Mississauga: 0
Scarborough: 0
Windsor: 0
These are estimated number of days using averages of past orders for inventory arriving to each branch location and are not guaranteed. If you need to verify manufacturer stock please email customercare@amresupply.com or call us at 1-800-661-9891.
Amre Branch # of Days
Calgary: 21
Edmonton Downtown: 23
Edmonton South: 18
Hamilton: 20
London: 15
Mississauga: 18
Richmond: 22
Saskatoon: 19
Scarborough: 16
Surrey: 22
Windsor: 10
Winnipeg: 16


Product Specifications

  Differential Temperature (F): High limit : 10 F fixed; low limit: 10-25 F adj.
  Dimensions (in): 4 3/8 in. high x 6 1/8 in. wide x 3 1/16 in. deep
  Dimensions (mm): 111 mm high x 156 mm wide x 78 mm deep
  Electrical Connections (in): Quick-Connect / Screw
  Electrical Ratings, Burner: At Full Load-- Line Voltage: 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- Line Voltage: 44.4 A @ 120 Vac: 22.7 A @ 240 Vac
  Electrical Ratings, Circulator: At Full Load-- 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- 44.4 A @ 120 Vac: 22.2 A @ 240 Vac
  Frequency: 60 Hz
  Maximum Safe Operating Pressure (kPa): 1378 kPa on outside of immersion well, 690 kPa on capsule if inserted directly.
  Maximum Safe Operating Pressure (psi): 200 psi on outside of immersion well, 100 psi on capsule if inserted directly.
  Operating Humidity Range (%RH): 0 to 95% RH, non-condensing
  Operating Temperature Range (C): High Limit-- 54 C to 116 C; Low Limit-- 43 C to 104 C
  Operating Temperature Range (F): High Limit-- 130 F to 240 F; Low Limit-- 110 F to 220 F
  Switch Action: Single Pull, Single Throw: High & Low Limit
  Temperature Range (C): -34 C to 66 C at switches; 129 C at sensing element
  Temperature Range (F): -30 F to 150 F at switches; 265 F at sensing element
  Volts (V): 24 Vac; 120 Vac

Product Downloads
  Product Specifications
  Installation Instructions

Customer Reviews


  Add a Customer Review