Lennox 63W26 2 Stage Ignition Control Board.
Use with Lennox Furnace Models G60DF-36A-070X-07, G60DF-36A-070X-09, G60DF-36B-090-07, G60DF-36B-090-09, G60DF-48C-110-09, G60UH-24A-070-09, G60UH-24A-070-10, G60UH-36A-070X-10, G60UH-36B-090-10, G60UH-36C-110-09, G60UH-36C-110-10, G60UH-48B-090-10, G60UH-48B-090X-10, G60UH-48C-110-09, G60UH-48C-110-10, G60UH-60C-110X-08, G60UH-60C-110X-1G60UH-60D-135-07, G60UH-60D-135-08, G60UH-60D-135-1,G61MP-36B-045-09, G61MP-36B-070-09, G61MP-36B-071-07, G61MP-48C-090-08 09, G61MP-48C-110-07 08, G61MP-60C-090-07, G61MP-60C-091-08, G61MP-60C-111-08

Replaces 23W25, 23W2501, 63W2601, 100869-01, 100869-02, 100869-03

Size: 8-3/16" x 4-3/16"
Line Voltage: Line 120V (97-132 VAC), 50/60 Hz
Current Draw: 0.5A Input Current, Plus Valve Load @ 24VAC
Igniter Current: 1.0A Resistive @ 95 VAC Output
Prepurge: 5 Seconds
HSI Warmup: 20 Seconds
Trial for Ignition: 4 Seconds
Postpurge: 5 Seconds
Interpurge: 15 Seconds
Auto Restart Delay: 60 Minutes (After Soft Lockout)
Ignition Trials: Five, Four Retries If Flame Is Not Sensed On The First Trial•Second Stage Recognition Delay: 30 Seconds (Only On First Call For High Fire On A Call For Heat)
Second Stage ON Delay: 10 Or 15 Minutes (Depending On Dip Switch S1 Setting For Switch 2) When Used With A Single-Stage Thermostat•Second Stage Fan OFF Delay: 30 Seconds
Flame Failure Response Time: 2 Seconds Maximum @ 1A
LEDs: Two LEDs Provide The Following: A Red LED Provides System Status And Faults, A Green LED Shows Information About The EnviraCOM Traffic
Heat Fan ON Delay: 45 Seconds
Heat Fan OFF Delay: 60, 90, 120 or 180 Seconds (Depending On Dip Switch S1 Settings For Switches 3 And 4)
ool Fan ON Delay: 2 Seconds
Cool Fan OFF Delay: 2 Or 45 Seconds (Depending On Dip Switch S1 Setting For Switch 5)
Gas Control: Any VAC Redundant, Direct Ignition Gas Control Rated At 1.5A Or Less. Honeywell VR8205 Recommended
Cooling Contactor: Any 24 Vac Contactor Rated At 1.0A Or Less
Induced Draft Blower: 2.2 FLA/25LRA Maximum @ 120VAC
Circulator Load: 14.5FLA/25LRA Maximum @ 120VAC

















Stock shown on hand can change at anytime without notice or may already be spoken for. Please inquire by phone to confirm precise amounts available at that time.
Alberta
Edmonton (DC): 0
Edmonton (South): 0
Calgary: 0
British Columbia
Richmond: 0
Surrey: 0
Manitoba
Winnipeg: 0
Saskatchewan
Saskatoon: 0
Ontario
Hamilton: 0
London: 0
Mississauga: 0
Scarborough: 0
Windsor: 0
These are estimated number of days using averages of past orders for inventory arriving to each branch location and are not guaranteed. If you need to verify manufacturer stock please email customercare@amresupply.com or call us at 1-800-661-9891.
Amre Branch # of Days
Calgary: 14
Edmonton Downtown: 11
Edmonton South: 10
Hamilton: 11
London: 17
Mississauga: 14
Richmond: 22
Saskatoon: 9
Scarborough: 15
Surrey: 17
Windsor: 13
Winnipeg: 17

Customer Reviews


  Add a Customer Review

1P63W26
T003495832
T003913484